Samsung Refrigerators2017–present

Error Code C FAN ERROR

Compressor is not getting adequate cooling air flow

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: C FAN ERROR

What This Means

Voltage between CN32-12 and CN32-13 not within 7V-12V range; Fan motor mechanical failure or blockage; Bad wiring connection or loose connector; Pulse signal not reaching MICOM from fan rotation; MICOM ground connection problem

What actually causes this:

Condenser fan frozen from water or mechanical bearing failure in motor

First Thing to Check

Inspect compressor cooling fan area for ice or debris accumulation

Parts Involved

Compressor Cooling BLDC Fan MotorConnector CN32Main PCB

How to Fix

  1. 1

    1. Measure voltage between CN32-12 and CN32-13 (should be 7V-12V DC)

  2. 2

    2. Verify pulse signal (CN32-11) alternates between 0V and 2-3V

  3. 3

    3. Inspect compressor cooling fan for ice or debris

  4. 4

    4. Check wiring connection to CN32

  5. 5

    5. Verify MICOM ground connection at J23 jumper and CN76-4 (orange)

  6. 6

    6. Check for soldering issues on PCB near CN32

This Error Applies To

Samsung DRF36C100SR Series Refrigerators (2017) (2017–present)

Service manual exact match: DRF36C100SR